Contact Us Now for a Free Professional Fireplace Remodeling estimate 647-713-0259 ClickFire.ca@gmail.com
Cart 0
Volta Pellet Stove

Osburn

Volta Pellet Stove

$5,799.00 $6,000.00

The Volta, Osburn’s newest pellet stove, is a quiet and contemporary model. Its innovative components use direct current (DC) and can now operate using the optional 24 volt battery system in the event of a power interruption. The unit can also be easily connected to solar panels or other secondary source of renewable energy.

The Volta is the complete package, an environmentally friendly heater that delivers power, efficiency, reliability and cleanliness.

APPLIANCE PERFORMANCE (1)

Fuel type : Pellet (Premium grade or better) (2)
Recommended heating area (sq.ft.) : () 500 - 2,000
Hopper capacity : 60 lb (27 kg)
Maximum burn time : () 50 h
Maximum heat input rate : (3) 45,600 BTU/h (13.4 kW)
Overall heat output rate (min. to max.) : (4) 7,200 BTU/h (2.1 kW) to 24,800 BTU/h (7.3 kW)
Average overall efficiency : (5) 62.8 % (HHV) (6) 67.7 % (LHV) (7)
Optimum efficiency : (8) (9) 75 %
Burn rate : 1.2 - 5.3 lb/h
Average particulate emissions rate : (10) 2.5 g/h
Average CO : (11) 111.8 g/h
Average electrical power consumption for ignition cycle :(12) 1.6A (192W)
Average electrical power consumption for continuous operation : (12) 0.3 - 0.6A (36 - 72W)

(1) Values are as measured per CSA B415.1-10, except for the recommended heating area, hopper capacity, maximum burn time and maximum heat input rate. Results may vary depending on pellet quality, density, length, and diameter.

(2) Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.

(3) Based on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU/lb.

(4) As measured per CSA B415.1-10 stack loss method.

(5) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.

(6) Higher Heating Value of the fuel.

(7) Lower Heating Value of the fuel.

(8) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

(9) Optimum overall efficiency at a specific burn rate (LHV).

(10) This appliance is officially tested and certified by an independent agency.

(11) Carbon monoxyde.

(12) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.

GENERAL FEATURES

Combustion technology Bottom-feed
Clearance – top (measured from the floor) 14 5/8"
Centre line of flue outlet to the side 4 3/8"
Noise level at 6 feet 45 dBa (+/- 3 dBa) - 52 dBa (+/- 3 dBa)
Chimney diameter 3"
Baffle type Stainless steel
Approved for a mobile home installation Yes
Weight 411 lb (186 kg)
Door type Single, glass with steel frame
Glass type Ceramic glass
Glass surface – dimensions (Width X Height) 5 3/4" X 10"
Overall dimension (Height) 41 1/8"
Overall dimension (Width) 21 3/4"
Overall dimension (Depth) 28 1/8"
Centre line of flue outlet to the side 4 3/8"
Centre line of flue outlet to the floor 14 5/8"
Voltage and frequency 88 - 264 VAC (47 - 63 Hz)
AC Current 3.6A/115VAC - 1.8A/230VAC
Battery back-up 24V DC (20 Ah)
Main control board fuses ATC 7.5A 32VDC
Battery back-up control board fuses ATC 7.5A 32VDC
Power cord inlet socket fuse 3A / 250V (5 X 20)
Main board battery CR2032
USA standard (emissions) EPA
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 1482, ASTM E1509
Canadian standard (safety) ULC S627
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime
Minimum clearances to combustibles *
(Data expressed in inches. 1 inch = 25.4 mm)
  Canada USA
Back 1" 1"
Sides 4" 4"
Corners 1" 1"
Top ** 54" 54"

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Measured from the platform on which the product is installed. Some appliances have been tested with a low ceiling. If necessary, consult the owner's manual for information on these clearances to combustible materials.